EasyManua.ls Logo

Wacker Neuson AR - Page 51

Wacker Neuson AR
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19 Technical data
51 100_0102_td_0006.fm
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[mm
2
]
AR63/6/250 250 3~ <
150 (492.1) 1,5
AR64/1,5/400 400 3~ <
150 (492.1) 1,5
AR64/3/230 230 3~ <
150 (492.1) 1,5
AR64/3/400 400 3~ <
150 (492.1) 1,5
AR64/6/042 42 3~ <
15 (49.2) 4
<
22 (72.2) 6
<
34 (111.5) 10
AR64/6/250 250 3~ <
150 (492.1) 1,5
AR64/9/042 42 3~ <
20 (65.6) 4
<
30 (98.4) 6
<
47 (154.2) 10
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[AWG]
AR63/6/250 250 3~ < 150 (492.1) 16
AR64/1,5/400 400 3~ <
150 (492.1) 16
AR64/3/230 230 3~ <
150 (492.1) 16
AR64/3/400 400 3~ <
150 (492.1) 16
AR64/6/042 42 3~ <
12 (39.4) 12
<
19 (62.3) 10
AR64/6/250 250 3~ <
150 (492.1) 16
AR64/9/042 42 3~ <
11 (36.1) 14
<
17 (55.8) 12
<
26 (85.3) 10

Table of Contents

Related product manuals