11 Maintenance
100_0202_mt_0005.fm 33
11.2.3 Checking the water separator
1. Place the machine upright on a flat surface.
2. Switch off the engine.
3. Check whether there is water in the inspection glass of the water separator.
4. If necessary, unscrew drain plug and catch water in a collecting container.
If fuel comes out rather than water, re-tighten the drain plug.
Note: Dispose of the water in accordance with the applicable environmental regu-
lations.
Item Designation
1 Inspection glass
2Drain plug

Table of Contents