9 Operation and use
100_0202_op_0009.fm 31
9.4.2 Reading Compatec – compaction display
This display roughly indicates the progress of the compaction.
The number of LEDs lit is proportional to the soil density, more illuminated LEDs corresponds to a
higher soil density.
9.5 Decommissioning
9.5.1 Decommissioning the machine
1. Put the throttle lever back to the detent.
2. The engine comes to a standstill.
NOTICE
To protect the machine, the display unit warns the operator of over-compaction by quickly
flashing all LEDs. The brightness of the LED automatically adjusts to the light conditions
of the working area.
NOTICE
It is possible to detect missing spots (non-compactable material) if the spot is longer than
one meter.
In the case of abrupt change from high to low-compacted soil (or vice versa), there is a
slow increase or decrease of the LEDs.
NOTICE
Do not decommission the machine with the decompression lever, since this inevitably
leads to damage to the machine or engine.