BA E19 en* 1.0 * E19_10_700.fm 7-5
Maintenance 7
Other maintenance intervals (Wacker Neuson service center):
Every 500 operating hours or annually
Every 1000 operating hours
Every 1500 operating hours
Every 2000 hours of operation or every two years
Every 3000 operating hours or every 3 years
For additional details contact a Wacker Neuson service center.
Information
Maintenance with the note authorized service center must be performed
only by the trained and qualified personnel of an authorized service
center.
Check the hydraulic quickhitch (Easy Lock) for damage --
Check the Powertilt for damage --
Weekly maintenance (every 50 operating hours) (operator) Page
Lubricate the vehicle according to the lubrication schedule 7-7
Check accesses and exits for dirt --
Actuate the Powertilt swivel device in the limit positions in both flow direc-
tions for one minute each to rinse the system
--
All steps for maintenance intervals once a day
--
1. Check the threaded fittings and corresponding components/assemblies visually or manually (without using tools) for tightness. Replace the threaded fitting in
case of irregularities. Pay attention to adhesive connections as you do so.
Daily maintenance (operator)
Only once after the first 50 operating hours (Wacker Neuson service center)
Replace the hydraulic oil filter --
Replace the gearbox oil (traveling drive)
1
--
Check V-belt condition and tension --
Check the threaded fittings for tightness
2
--
Check labels and Operator’s Manual for completeness and condition --
Check the pressure of the primary pressure limiting valves (operating hydraulics) --
All steps for maintenance once a day and once a week --
1. For the first time at 50 operating hours, then annually or latest after 1000 operating hours.
2. Check the threaded fittings and corresponding components/assemblies visually or manually (without using tools) for tightness. Replace the threaded fitting in
case of irregularities. Pay attention to adhesive connections as you do so.