9-8 BA E19 en* 1.0 * E19_10_900.fm
9 Technical data
9.10 Coolant
Compound table
9.11 Noise emissions
Measurements performed on asphalted surface.
9.12 Vibrations
Outside tempera-
ture
1
1. Use the 1:1 concentration for warm outside temperatures, too, to ensure protection against corrosion,
cavitation, and deposits.
Distilled water Coolant
2
2. Do not mix the coolant with other coolants.
Up to °C (°F) % by volume % by volume
-30 (-22) 50 50
Noise emissions
Measured sound power levelLwA
1
1. According to ISO 6395 (EC Directives 2000/14/EC and 2005/88/EC)
97 dB(A)
Guaranteed sound power level LwA
1
97 dB(A)
Vibrations
1
1. Uncertainty of measurement as per DIN EN 474-1:2014-03
Effective acceleration value for the upper extremi-
ties of the body (hand-arm vibration)
< Trigger value
< 2.5 m/s
2
Effective acceleration value for the body (whole-
body vibration)
< 0.5 m/s
2