Warning No. Warning Cause Remedy
E01 Atomizing air too low Set point cannot be reached
Causes:
– Hose kinked / blocked – Check hoses and hose laying
– Input air pressure too low – Ensure that input pressure is
greater than 6 bar
– System cannot reach target
setting
– Check gun and nozzle
system
E02 Dosing air too low Set point cannot be reached
Causes:
– Hose kinked / blocked – Check hoses and hose laying
– Input air pressure too low – Ensure that input pressure is
greater than 6 bar
– Injector is not connected – Connect injector correctly
– System cannot reach target
setting
– Check hoses and hose laying
E03 Feed air too low Set point cannot be reached
Causes:
– Hose kinked / blocked – Check hoses and hose laying
– Input air pressure too low – Ensure that input pressure is
greater than 6 bar
– Injector is not connected – Connect injector correctly
– System cannot reach target
setting
– Select smaller set point value
Example: Feed air for ED
pump max. 3.5 Nm³/h
E04 Fallen below Tribo
current limit for 10 s
The Tribo current set in the
conguration cannot be
reached
Causes:
– Tribo air set too low – Increase Tribo air
– Powder not owing due to
incorrect settings for feed air
and total air
– Correct feed air and total air
settings
– No powder in tank – Fill powder tank
– The powder does not have
the required charging
characteristics
– Use suitable powder