53
EPG-SPRINT XE
P_01768
kV
80
60
40
20
100
Tri Cor
5
4
3
2
1
120
80
40
20
10
µA
P_01758
32
31
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2354913
7.7.8 SETTING THE U/I CHARACTERISTIC CURVES
Procedure:
To change the characteristic slope, press the
"Characteristic Slope" button 31 once or twice until the
desired characteristic curve is shown in the "Characteristic
Slope" LED display 32.
U/I characteristic curves for EPG-SPRINT XE
The user can choose from three characteristic curves to achieve optimum coating results.
These enable optimum electrostatic charging of the powder despite dierent powder
characteristics.
Standard
Medium
Soft
High voltage [kV] 100 kV
Spray current [µA]
120 [µA]
The properties of the various characteristic curves and their use are described on the
following page.