77
EPG-SPRINT XE
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2354913
Fault number Malfunction Cause Remedy
E54 Hardware error Hardware defect has
occurred
Detach hose on rear of
valve and in standby mode,
check the valve for seal
integrity (air supply must
be connected)
Atomizing air duct valve
leaking
E55 Hardware error Hardware defect has
occurred
Detach hose on rear of
valve and in standby mode,
check the valve for seal
integrity (air supply must
be connected)
Dosing air duct valve
leaking
E56 Hardware error Hardware defect has
occurred
Detach hose on rear of
valve and in standby mode,
check the valve for seal
integrity (air supply must
be connected)
Feed air duct valve leaking
E60 Operation without
external release (only
for manual gun with
external control)
No release from Check external control
Missing or defective wiring