77
EPG-SPRINT XE
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2354913
Fault number Malfunction Cause Remedy
E54 Hardware error – Hardware defect has
occurred
– Detach hose on rear of
valve and in standby mode,
check the valve for seal
integrity (air supply must
be connected)
– Atomizing air duct valve
leaking
E55 Hardware error – Hardware defect has
occurred
– Detach hose on rear of
valve and in standby mode,
check the valve for seal
integrity (air supply must
be connected)
– Dosing air duct valve
leaking
E56 Hardware error – Hardware defect has
occurred
– Detach hose on rear of
valve and in standby mode,
check the valve for seal
integrity (air supply must
be connected)
– Feed air duct valve leaking
E60 Operation without
external release (only
for manual gun with
external control)
– No release from – Check external control
– Missing or defective wiring