19
EPG-SPRINT.
OPERATING MANUAL
VERSION 08/2010 ORDER NUMBER DOC 2305222
● To activate the function, the current limiting is set with the rotary controller 24 and
is indicated in the LED display 19.
● Adjusting range: 5-120 µA
● Resolution: 1 µA
30 Display LED: Current limiting
● Lights up yellow. The current limiting is selected and can be adjusted using
knob 24.
31 Push button: Characteristic slope
● To switch the characteristic slope.
● Display with LED 32.
32 Display LED: Characteristic slope
● Lights up green.
● Lower LED characteristic curve, fl at.
● Middle LED characteristic curve, medium.
● Upper LED characteristic curve, steep.
33 Illuminated display: Powder quantity
● Lights up green.
● Display range: 0-100%
● Resolution: 3.33%
● Single LED display: Set point (high-voltage and powder are deactivated).
● Bar graph LED: Actual value (high-voltage and powder are activated).
34 Illuminated display: Overall air quantity
● Lights up green.
● Display range: 2-6 m³/h
● Resolution: 0.2-0.5 m³/h
● Single LED display: Set point (high-voltage and powder are deactivated).
● Bar graph LED: Actual value (high-voltage and powder are activated).
35 Illuminated display: Atomizing/ionising/Tribo air quantity
● Lights up green.
● Display range: 0.1-4 m³/h
● Resolution: 0.1-1.0 m³/h
● Single LED display: Set point (high-voltage and powder are deactivated).
● Bar graph LED: Actual value (high-voltage and powder are activated).
36 Push button: Powder quantity
● To activate the function, the high-voltage is set with the rotary controller 24 and is
indicated in the LED display 19.
● Adjusting range: 1-100%
● Resolution: 1%
37 Display LED: Powder quantity
● Lights up yellow, when the powder quantity is selected.