VERSION 08/2010 ORDER NUMBER DOC 2305222
19 Display LED: 7 segments, three-digit number
Indicates the exact value depending on the activated function:
“Overall air quantity; atomizing, ionising and Tribo air; additional recipes;
high-voltage; current limiting; powder quantity“.
Displaying error number about malfunctions and warnings.
20 Push button: Overall air quantity
To activate the function, the value is precisely adjusted with the rotary controller 24
and is indicated in the LED display 19.
Adjusting range: 2-6 m³/h
Resolution: 0.05 m³/h
21 Push button: Atomizer, ioniser, Tribo air
To activate the function, the value is precisely adjusted with the rotary controller 24
and is indicated in the LED display 19.
Adjusting range: 0.1-4 m³/h
Resolution: 0.05 m³/h
22 Display LED: Overall air
Lights up yellow, when the setting “Overall air“ is selected.
23 Display LED: Atomizer, ioniser, Tribo air
Lights up yellow, when the setting Atomizing, ionising and Tribo air“ is selected.
24 Universal rotary controller
Dynamic digital rotary controller with 32 positions per revolution.
Adjustment speed is proportional to rotational speed.
Used to set: “Overall air quantity; atomizer, ioniser, Tribo air; additional recipes;
high-voltage; current limiting; powder quantity“.
For setting parameter values in configuration mode.
25 Push button: Additional programs
To activate the function, the additional program is set with rotary controller 24 and
is indicated in LED display 19.
Selection of programs 5 to 50.
26 Display LED: Additional programs
Lights up yellow when an additional program is selected.
27 Push button: High-voltage
To activate the function, the high-voltage is set with the rotary controller 24 and is
indicated in the LED display 19.
Adjusting range: 10-100 kV
Resolution: 1 kV
28 Display LED: High-voltage
Lights up yellow. The high-voltage is selected and can be adjusted using knob 24.
29 Push button: Current limiting