24
VM 500
B_03423
VM 500
12
34
OPERATING MANUAL
EDITION 03/2012 PART NUMBER DOC 2318724
7 TROUBLE SHOOTING AND SOLUTION
Functional fault Cause Remedy
Green illuminated display (2)
does not light up
No illuminated display lights
up
• Mains not switched on.
• Fuses defective.
• Switch on mains power supply.
• Replace fuse.
• WAGNER Service.
Green illuminated display (1)
does not light up,
no high-voltage
• Spray gun cable not connected or
defective.
• Spray gun not connected or
defective.
• Connect spray gun cable.
• WAGNER Service.
Green illuminated display (1)
always lights up
• Spray gun or control unit
defective.
• WAGNER Service.
Green illuminated display (1)
lights up, no high-voltage
• Excessive conductivity of the
paint.
• See spray gun operating manual.