32
GM 5000EAC.
1/2
1
2
B_03160
B_03161
1
2
OPERATING MANUAL
EDITION 03/2012 PART NUMBER DOC 2319150
5.4.3 CLEANING OF CLOGGED ROUND JET NOZZLES
1. Remove nozzle insert (1) using nozzle
spanner (2).
2. Fit the new nozzle insert.
1. By means of nozzle spanner (2), loosen nozzle
insert (1) by a half turn.
2. Remove the nozzle spanner and briefl y
actuate trigger guard.
3. After cleaning the nozzle, re-tighten the
nozzle insert.
5.4.4 EXCHANGE OF ROUND JET NOZZLE INSERT
DANGER
Exploding gas/ air mixture!
Danger to life from flying parts and burns
Never spray into a closed container.
Earth the container.
SIHI_0008_GB