Operating manual Manual Powder System SPRINT XE
7 Operation
40 Order number 2354920 | Edition 01/2023
7.5.2 60 L tank version
7.5.2.1 Cleaning process when using a single powder tank
Info
For a paint change, all components of the powder feed system must be thoroughly
cleaned.
P_05051
EPG
SPRINT X
0
%
10
20
30
40
50
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
80
100
%
Tri
90
60
70
17
1. Release the trigger lever on the spray gun.
ð The high voltage and the powder feed are deactivated.
2. Remove the injector from the holder to stop powder feed.
3. Hold the gun in the spray booth and start the flush function by pressing the
[Flush]button(17).
ð The injector and hoses are flushed.
4. Switch off control unit.
5. Open the powder tank and clean all powder feeding parts such as: the spray gun, the
powder injector, the powder feed hose and the suction system.
6. Clean the powder tank and pay special attention to the fluid base.
Info
Proper fluidization is not possible with a damaged and/or clogged fluid base.
To adapt the programs to the new applications, proceed as described in the EPG-Sprint XE
control unit's operating manual.