6.2.2 Optical Interface O1
The O1 optical interface comes with a total of eight light diodes (se also figure xyz); they indicate the
system statuses of the WLVCM:
LED
Name
Value
Specification
1 Error temperature
ON
Temperature not within tolerance range
OFF
Temperature within tolerance range
2 Error current limitation
ON
Authorized current for clamp “Valve +“ exceeded
OFF
Current at clamp “Valve +“ below limit value
3 Ready for start
ON
WLVCM ready for operation
OFF
WLVCM not ready for operation
4
Shot/shot sequence
active
ON
Currently an application is carried out
OFF
No application active
5
Shot/shot sequence
finished
ON
Application finished
OFF
Application not finished
6 +24V
ON
Operating voltage 24VDC available
OFF
No / wrong operating voltage available
7 Operating status
ON
Active date transfer between WLVCM and configuration
tool
OFF
No active data transfer between WLVCM and
configuration tool
8 Input start
ON
Start signal applied (clamps „Start and „Start +“)
OFF
Start signal not applied
Table 9 – Light diodes of the optical interface O1 and their relevance