EasyManua.ls Logo

WAMGROUP MBF - 7.1 Cleaning the Valve; 7.2 Lubrication

Default Icon
187 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.0 INFORMATION REGARDING MAINTENANCE
VL
2
VAL.130.--.M.EN Issue: A1
09.16
41
7.2 Lubrication
Lubrication operations have to be carried out (see periodic check maintenance), using conductive type grease
pastes on the following parts:
- Connecting shaft;
- Earth wiring contact screw.
N.B.: A routine lubrication cycle is only recommended for the CRGX electromechanical control, with grease
suitable for ATEX applications applied on the bronze block approx. every 300 opening/closing cycles.
7.1 Cleaning the valve
Clean the outside part of the valve using a vacuum cleaner to prevent dispersal of dust in the environment and
in the surrounding area, or use a moist cloth.
Do not use compressed air under ATEX condition.
Wash the valve, after vacuuming the dust, with a low-pressure water jet.
Before start-up the valves for food applications (model F and P), has to be subjected to cleaning and sanitation
by means of a woven/non-woven cloth and sanitizer spray.