Fil Pilote (France only)
The thermostat can obey the 6
standard
commands of l pilote (pilot
wire) Contact
Warmup for additional details.
7. Set Overheat limit to protect
your oor.
Please note, the tempo
will only allow you to set a
temperature 2°C/4°F lower
than the Overheat limit
30°C
8. Set an offset value to calibrate
the temperature reading of your
thermostat sensors
0°C
The thermostat is not controlling the
temperature
Ensure that the Program Slide is in the run position (lowest point) and that the
Mode Slide control (bottom) is in the manual or program positions.
Floor sensor error
If you see the oor sensor error icon or “ - - “ on the screen it means that your
thermostat has been unable to detect the temperature of the oor. Please contact
Warmup.
Overheat
If you see the overheat icon this means that your oor has become too hot
and the heating has been suspended. Please contact Warmup.
Low battery
The low battery icon will display when the battery needs to be replaced. The
thermostat must be connected to the mains electricity supply in order to work, it
is not designed to be used with an intermittent power supply. If the battery is not
installed then your thermostat will not be able to maintain the clock time if power is
lost.
Heating starts too early If your heating is coming on too early, then this may be because the Adaptive
Learning function is turned on. This function allows your thermostat to learn how
long it will take to heat up to ensure it is the correct temperature at the start of the
comfort periods. See “installer settings” section of this guide.
Incorrect calibration Your thermostat should not need any calibration, however if you would like to apply
an offset to the temperature settings see the “installer settings” section.
No mains electricity
If you see the no mains power icon this means that the thermostat is not
receiving power. Check that the thermostat logic module is properly installed on
the power module and that the 230V mains electricity supply is connected.
Regulator mode (Reg) is displayed In this mode your thermostat will come on for a set number of minutes in a 10
minute cycle. The thermostat will not use the temperature for control. Please
contact Warmup for additional details.
Fil Pilote (FP) is displayed The thermostat can obey the 6 standard commands of l pilote (pilote wire).
Please contact Warmup for additional details. (France only)
HI or LO is displayed
The thermostat will display “HI” if the ambient temperature exceeds 50°C (122°F)
and “LO” when the ambient temperature falls below 0°C (32°F).
Maximum Overheat Limits
Tiles 40°C / 104°F
Stone 40°C / 104°F
Wood / Laminate 28°C / 86°F
Carpet 28°C / 86°F
Vinyl 28°C / 86°F
ELT-01-XX-01 - Operating guide V1.0 © Warmup plc - 2013
Error messages / Trouble shooting