16.6 Exhaust noise
The exhaust noise is measured as a sound power level according to ISO 9614-2. The results
are presented with A-weighting in octave bands, reference level 1 pW. The values presented
in the graphs below are typical values, cylinder specific graphs are included in the Installation
Planning Instructions (IPI) delivered for all contracted projects.
Fig 16-5 Typical sound power levels of exhaust noise, W L46F
Fig 16-6 Typical sound power levels of exhaust noise, W V46F
16-6 Wärtsilä 46F Product Guide - a19 - 1 December 2017
Wärtsilä 46F Product Guide16. Vibration and Noise