23833A115
2
10-1/2" Minimum
4-1/8" - R3V, R5V
7" - R2SA, R3S, R5S-1
1-1/2" Check Valve RCV-12S
for 1-1/4" and 1-1/2" pipe
Sump basin 14" to 18" in diameter
made of plastic, fiberglass, or
concrete
Bottom of
inlet pipe
Turn-off level
Turn-on level
Lifting Handle
1/8" Relief
Hole (5"
above pump
opening)
Male PVC Adapter
PVC Pipe (15" long)
Shutoff gate valve
(optional)
Grounded type 115 volt
receptacle. Minimum height of
4 feet above floor.
Discharge piping can be PVC or
galvanized steel (1-1/2" for R2SA,
R3S, R3V, R5S-1 & R5V). The head
(vertical distance to discharge)
should not exceed values shown
in chart.
Float Switch
12" Minimum - R3V
14" Minimum - R2SA, R3S, R5S-1 & R5V
5-3/4" - R3V
9-1/2" - R2SA
10" - R3S
8-1/2" - R5V
11" - R5S-1
Complete Pump Installation
PUMP
MODEL
TOTAL HEAD (vertical pumping distance) IN FEET
2468
20 22
18
14
16 12
10
R2SA
R3S, R3V
R5V, R5S-1
PERFORMANCE TABLE (in gallons per minute)
30 28 27 26 25 18 15 12 9 4
35 33 32 31 30 24 22 19 16 11 6
60 60 58 55 53 48 43 38 30 22 11