Control Start-up Procedures
Models
FF-844M, FF-844EM, FF-844T
FF-948M, FF-948EM, FF-948T
FFE-1054M, FF-1054EM, FF-1054T
FFC-835M, FFC-835EM, FFC-835T
For replacement copies of these manual please contact Fleet Farm.
Programming
Setting time of day for all units
Set time of day: Press RED TIME SET BUTTON and turn 24 HOUR GEAR until present time of day is aligned with
TIME OF DAY arrow. Figure 5
Figure 5 Figure 6
Programming metered softener control
Note: Hardness and iron can be found on Page 3.
Note: The manufacturer's predetermined salt setting is the most effective setting for your particular model. All
softeners are set for a medium capacity salt setting which can be found under CAPACITY & PERFORMANCE
SPECIFICATIONS on Page 2.
Check Salt Setting: Check the label on the back timer cover for the salt setting. Remove back cover and make sure
the setting is correct. The salt cam is on the left hand side of the control. See flow diagram 8.
To program water softener: First you must know the hardness and iron content of your water. Set regeneration
program by lifting (pulling) and rotating the PEOPLE DIAL so the number of people in the household is aligned with
the "compensated" GRAINS PER GALLON of hardness (hardness dial) of your water.
Grains per Gallon of Hardness + (4 x Iron ppm) = Compensated hardness