CUBE Manual Page 35 - Revision: 5-24-2017
BYPASSING COVER PIN
If pin on back of the cover breaks off, the unit will be disabled.
To bypass in the event this occurs:
1.
Remove Top Cover
2.
Remove 5 screws from inner top cover to access electronics:
3.
Locate interlock switch at rear of unit two brown wires with white
quick connects:
4.
Bypass the interlock by looping the two brown wires that go to the
interlock together and leave the switch unplugged:
5.
Tuck wires back into place and reinstall covers: