CUBE Manual Page 81 - Revision: 5-24-2017
HOT WATER TROUBLESHOOTING
1. Hot Water is not Hot 187°F (86C°)
2. Hot Water is not Available
Resetting Hot Tank Overload and Programming the DIP Set-Up for Hot Water
Temperature Instructions are included in this Troubleshooting section.
1. Hot Water is not Hot 187°F (86°C) +/- 5°F
Possible Reason
Solution
No power to Hot Tank
Check that the Green Heater and
Compressor switch is on.
Turn Green Heater and Compressor Switch
on. I = ON
Tank has run out of Hot W
ater.
Hot Tank Capacity is 1.3 liters.
Wait for Hot Tank to heat water to temperature prior to
dispensing more hot water.
Greater Water Capacity Waterlogic Water Systems are
available.
Hot Water Temperature
Programming
Verify that the CUBE has been programmed to desired
temperature. See Programming: Hot Water Temperature DIP
Set-Up Instructions in this Troubleshooting Section.
2. Hot Water is not Available
Possible Reason
Solution
Hot Tank Overload Tripped
Reset Hot Tank Overload.
Hot Tank Overload Instructions in this Troubleshooting
Section.

Related product manuals