Summary

Safety Instructions

Pacemaker Warning

Magnetic field near magnets can affect pacemakers, ICDs, and other implanted medical devices.

General Handling Precautions

Device must be switched off before moving, handled with caution, used indoors, and maintained by representatives.

About This Manual

Product Overview

Visual guide to the Magnet+ device components including LED indicator, labware holder, power button, and connectivity ports.

Getting Started

Initial Setup Procedure

Steps for powering the device, connecting to Wi-Fi, and launching the installation web browser for initial setup.

Operations

Protocol Design and Editing

Use the drag-n-drop editor to create precise experiment protocols, including magnetic field actions.

Executing Experiments

Select experiment setups and prepare materials for manual, semi-automated, or automated operation with Magnet+.

Technical Data and Device Operation

Device Specifications

Details on labware compatibility, environment, dimensions, weight, power, connectivity, and cleaning.

Multiple Connected Devices Installation

Step-by-step guide for connecting multiple devices, managing cables, and closing hatches.

Powering the Device

Instructions for turning the Magnet+ device on and off using the power button.

Unit End of Life and Certifications

Unit End of Life Policy

Contact Andrew Alliance for directions and information regarding the end-of-life policy for the unit.

Product Certifications

Lists certifications for electrical safety, EMC, radio, FCC compliance, and RoHS.

Summary

Safety Instructions

Pacemaker Warning

Magnetic field near magnets can affect pacemakers, ICDs, and other implanted medical devices.

General Handling Precautions

Device must be switched off before moving, handled with caution, used indoors, and maintained by representatives.

About This Manual

Product Overview

Visual guide to the Magnet+ device components including LED indicator, labware holder, power button, and connectivity ports.

Getting Started

Initial Setup Procedure

Steps for powering the device, connecting to Wi-Fi, and launching the installation web browser for initial setup.

Operations

Protocol Design and Editing

Use the drag-n-drop editor to create precise experiment protocols, including magnetic field actions.

Executing Experiments

Select experiment setups and prepare materials for manual, semi-automated, or automated operation with Magnet+.

Technical Data and Device Operation

Device Specifications

Details on labware compatibility, environment, dimensions, weight, power, connectivity, and cleaning.

Multiple Connected Devices Installation

Step-by-step guide for connecting multiple devices, managing cables, and closing hatches.

Powering the Device

Instructions for turning the Magnet+ device on and off using the power button.

Unit End of Life and Certifications

Unit End of Life Policy

Contact Andrew Alliance for directions and information regarding the end-of-life policy for the unit.

Product Certifications

Lists certifications for electrical safety, EMC, radio, FCC compliance, and RoHS.

Overview

The Waters Magnet+ is a laboratory device designed for automating magnetic bead-based protocols, integrating with the OneLab software for design and execution of experiments. It is part of the Andrew Alliance product line, a Waters Company.

Function Description:

The Magnet+ is a module that applies a magnetic field to labware, primarily for bead purification protocols. It works in conjunction with the OneLab platform, which allows users to design, execute, and monitor experiments. The device is capable of both manual and automated operation, supporting various experiment setups including fully automated, assisted and traced, and manual pipetting. It is designed to facilitate precise and complete protocols, guiding users through each step with visual instructions and recording all experiment data within OneLab.

Important Technical Specifications:

  • Labware Compatibility: Check the OneLab Domino Catalog at andrewalliance.com/domino-catalog for specific compatible labware. The images show compatibility with Deepwell Magnet and 96-PCR Plate Magnet+.
  • Relative Humidity: 80% at 37°C.
  • Maximum Operating Altitude: 2000 m.
  • Environment Temperature Operating Range: +4 to +37°C.
  • User Interface: Through OneLab software.
  • Ingress Protection: IP20* (Avoid spilling liquid on the device).
  • Dimensions (W x L x H): 170 x 162 x 115 mm (dimensions are subject to change according to the labware).
  • Weight: 1.65 kg.
  • External Power Supply: Input 100-240 VAC, 1.4 A / output 24 VDC, 5 A, 120 W.
  • Power or Current Rating: 5 A.
  • Overvoltage Category DC Port: Cat I.
  • Operating Voltage: 24 VDC.
  • Network Connectivity: Gigabit Ethernet, Wi-Fi 2.4 GHz and 5 GHz.
  • Pollution Degree of Intended Environment: Pollution degree 2.
  • Warranty: 1 year.
  • Certifications: CE, FCC, RoHS, WEEE.

Safety Instructions:

  • Magnets and Pacemakers: The magnetic field near the magnets can affect pacemakers, ICDs, and other implanted medical devices. Care must be taken to avoid deactivating such devices.
  • Movement: The device must always be completely switched off (cables removed) before moving it.
  • Handling: Handle with caution as it contains moving parts.
  • User Distance: Maintain a distance of at least 20cm from the product (WiFi antenna) during installation and operation.
  • Intended Use: For indoor use only.
  • Maintenance: Device maintenance must be done exclusively by an Andrew Alliance representative.
  • Protection Impairment: If the device is used in a manner not specified by the manufacturer, the protection provided may be impaired.
  • SELV Circuits: All input/output ports are Safety Extra Low Voltage (SELV) circuits and should only be connected to other SELV circuits.

Usage Features:

  • OneLab Integration: The Magnet+ works seamlessly with the OneLab software, allowing users to design protocols using a drag-and-drop editor.
  • Protocol Design: Users can create an "Apply magnetic field" action within OneLab protocols, specifying parameters for the magnetic field application.
  • Experiment Execution: OneLab automatically selects the appropriate Magnet+ device and allows for various experiment setups (manual, semi-automated, fully automated). Users prepare required materials based on the chosen setup.
  • Guided Experimentation: Visual instructions within OneLab guide users through each step of the experiment.
  • Data Recording: Every step of the experiment is recorded and available in OneLab.
  • Connectivity: Connects to a computer, tablet, or smartphone via Wi-Fi (network named Magnet-5xx.4XXX.XXXXX, where xxxx.xxxxx is the device serial number). Installation is initiated by launching a web browser and typing http://192.168.2.1.
  • Power On/Off:
    • Power On: When in standby mode (plugged in but off), press the power button to turn on. The device will also automatically start up when plugged into a power source.
    • Power Off: When the device is in an idle state (no experiment running), press the power button for 5 seconds to turn off.
  • LED Indicator: The LED indicator turns blue and blinks during installation mode and stops blinking when successfully connected to Wi-Fi.
  • Multiple Device Installation: The manual provides steps for connecting multiple devices, including placing them as indicated by OneLab, opening hatches, plugging in power cables, routing cables through dedicated paths, and closing hatches.
  • Built-in Components: Features a built-in computer and a built-in wireless adapter. It includes a power socket and an Ethernet port for cable connection.

Maintenance Features:

  • Cleaning: The device should only be cleaned with a wet tissue or isopropanol.
  • End of Life: When the unit reaches the end of its useful life, contact Andrew Alliance for directions and information on the end-of-life policy, in accordance with the European Union Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).