EasyManua.ls Logo

Watts SENTINEL LEAK DEFENSE LDS-3-075 - Page 27

Watts SENTINEL LEAK DEFENSE LDS-3-075
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
IOM-S-Leak Defense 2211 2022-03-15 © 2022 Sentinel Hydrosolutions, LLC
Figure 9
Positive Trigger from Security System to API
SECURITY PANEL I/O
ALARM ALARM
RELAY
#2
RELAY
#1
9-12VDC
5.5 x2.1mm
LED
TEST PB
Here are the valid MODE SEL combinations:
0 - H/A DIS, STBY DIS, POLD DIS
1 - H/A ENA, STBY DIS, POLD DIS
2 - H/A DIS, STBY ENA, POLD DIS
3 - H/A ENA, STBY ENA, POLD DIS
4 - H/A DIS, STBY DIS, POLD ENA
5 - H/A ENA, STBY DIS, POLD ENA
6 - H/A DIS, STBY ENA, POLD ENA
7 - H/A ENA, STBY ENA, POLD ENA
MODE SEL
NORMALLY
OPENZONE
LOOP
NEGATIVE
12VDC
TRIGGER
-12V GND
POSITIVE
12VDC
TRIGGER
GND +12V
B R
JUMPER
NC-RELAY IN
HOME MODE
NC COM NO
RB
GND IN+V+ -REF IN- IN+ +REF NO COM NC NO COM NCPOLD IN-
FOR TECHNICAL SUPPORT:
Please call our office at 1.866.410.1134 – 8:00am to 5:00pm Pacific Time
NORMALLY
OPEN ZONE
LOOP

Related product manuals