IOM-S-Leak Defense 2211 2022-03-15 © 2022 Sentinel Hydrosolutions, LLC
Figure 10
Negative Trigger from Security System to API
SECURITY PANEL I/O
POWER STANDBY HOME/AWAY ALARM ALARM
RELAY
#2
RELAY
#1
9-12VDC
5.5 x2.1mm
LED
TEST PB
Here are the valid MODE SEL combinations:
0 - H/A DIS, STBY DIS, POLD DIS
1 - H/A ENA, STBY DIS, POLD DIS
2 - H/A DIS, STBY ENA, POLD DIS
3 - H/A ENA, STBY ENA, POLD DIS
4 - H/A DIS, STBY DIS, POLD ENA
5 - H/A ENA, STBY DIS, POLD ENA
6 - H/A DIS, STBY ENA, POLD ENA
7 - H/A ENA, STBY ENA, POLD ENA
MODE SEL
NORMALLY
OPENZONE
LOOP
NORMALLY
CLOSED
ZONE LOOP
(DRY CONTACT INPUTS)
NEGATIVE
12VDC
TRIGGER
-12V GND
POSITIVE
12VDC
TRIGGER
GND +12V
B
R
R
B
JUMPER
NC-RELAY IN
HOME MODE
NC COM NO
GND IN+V+ -REF IN- IN+ +REF NO COM NC NO COM NCPOLD IN-
FOR TECHNICAL SUPPORT: