5.5 Verifying the received signal strength
The Fastrack modem establishes a call only if the received signal is sufficiently
strong.
To verify the received signal strength, do the following operations:
! Using a communication software such as Hyperterminal, enter the AT
command
AT+CSQ
.
The response returned has the following format:
+CSQ: <rssi>,<ber>
with:
o
<rssi>
= received signal strength indication,
o
<ber>
= channel bit error rate.
! Verify the
<rssi>
value returned which interpretation is given in the
table below.
Table 2: Values of received signal strength
Value of received signal
strength indication (<rssi>)
Interpretation of the
received signal strength
0 - 10 Insufficient(*)
11 - 31 Sufficient(*)
Greater than 99 No measure available
(*) Based on general observations.
For further information about AT commands refer to document [1].

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wavecom Technical data M1306B and is the answer not in the manual?

Wavecom Technical data M1306B Specifications

General IconGeneral
BrandWavecom
ModelTechnical data M1306B
CategoryModem
LanguageEnglish

Related product manuals