Barcode Scanner Module User Manual
18 / 57 Rev1.0 Date:180621
Note: The scanning command (UART) is that:7E 00 08 01 00 02 01 AB CD. The
scanner module will response bytes (02 00 00 01 00 33 31) for the command and
begin scanning at the same time.
Single Scanning Time
In command mode, this parameter set the max scanning time for per scanning
behavior. If the module success scanning or the its scanning time reach the max single
scanning time, module will enter the non-scanning interval. The range of single
scanning time should be 0.1~25.5s. If it is set to 0, it means that scanning time is
infinite. It is 5.0s by default.
LIGHTING AND TARGETING
1. Lighting
The white LED provides light for scanning, to improve the scanning performance
and supports weak light environments. It has three states for choice: