master valve.
Use the NEXT button to enter menu. Select setting for the ON Delay or OFF Delay by pressing NEXT. Use UP
and DOWN buttons to select delay time. Use UP and DOWN buttons to set ON Delay time from 0 seconds to
1 minute in 1 second increments. OFF Delay can be set from 0 seconds to 3 minutes in 1 second increments.
5.16 MV2 ZONE
A second master valve circuit can be enabled in this menu by designating a zone valve to be MV2
5.17 ZN/ZN DLY
This function allows user to set delay times between zone starts for use in systems with slow closing valves
or pump systems that are operating near maximum ow or have slow well recovery. Use UP and DOWN
buttons to change value. Adjustable in one-minute increments from 0 (the SmartLine® controller default
setting) to 30 minutes; adjustable in 10 minute increments from 30 minutes to 3 hours.
5.18 NUM START
This SmartLine® feature allows you to select the number of Watering Program Start Times that you want to
appear at Program Start Times on the dial. The default number of start times shown is 3. To select 1 to 8
start times, go to Advanced Functions, NUM STRT. Press Next to view the default of 3 start times. Scroll the
UP/DOWN buttons to select 1 to 8 start times to be visible on the dial. Return the dial to Run.
5.19 DS TIME
Your SmartLine® controller can automatically adjust the time for daylight saving time (DST). The factory
default setting is OFF and has been preset for the current USA schedule. To turn DST adjust ON, press the
next button at DS TIME, the NEXT button at ON/OFF then select ON.
The DS Time feature can be customized to match any international DST schedule. Press the NEXT button at
DS TIME in advanced functions. Select DS SETUP and press the NEXT button again. You will be prompted to
enter the START schedule (time of day is moved ahead 1 hour per START schedule), and the STOP schedule
(time of day is moved back 1 hour per STOP schedule). DST start and stop are formatted with the the Week
(rst, second, third, last), the Day (Sun-Sat) and the Month (Jan-Dec). All DS Time adjustments are made at 2
am. To return the DS Time schedule back to the USA factory default, use the US DEFLT option.
5.19.1
DST
ON/OFF
If you would like for your controller to automatically set the time of day on the
occurrence of Daylight Saving Time, make sure it is turned on in this menu
5.19.2
DS
SETUP
Your controller is programmed with the a default of starting Daylight Saving Time
starting on the second Sunday in March and ending on the rst Sunday in November. If
you would like to adjust these settings, you may do so in this menu.
5.20 RUN/SOAK
The purpose of Run/Soak is to break up long run times that often cause wasteful runo. The Run/Soak is
programmable for each program if you are using the BASIC watering mode. Note: If you are using SMART,
these inputs are not used since the Run/Soak period is automatically calculated.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Weathermatic SmartLine Controller and is the answer not in the manual?

Weathermatic SmartLine Controller Specifications

General IconGeneral
BrandWeathermatic
ModelSmartLine Controller
CategoryController
LanguageEnglish

Related product manuals