Frigo Top 10 - 43 | Pordoi 2000 - 4000 17
10.4.4 Fans
Label Description
Refrigerant Program level
R134 R134a with defrost R404A 1 2
FnC Fan operating mode C-y C-y C-n 1
Fnd Fan delay after defrost 0 0 2 2
FSt Fan stop temperature 50 50 50 1
Fon Fan on time with compressor off 0 0 0 2
FOF Fan off time with compressor off 0 0 0 2
10.4.5 Alarms
Label Description
Refrigerant Program level
R134 R134a with defrost R404A 1 2
ALC Temperature alarms configuration Ab Ab Ab 2
ALU Maximum temperature alarm 110 110 110 2
ALL Minimum temperature alarm -50 -50 -50 2
ALd Temperature alarm delay 15 15 15 2
dAo Delay of temperature alarm at start up 1.3 1.3 1.3 2
SE Regular service has to be performed (x10 hours) 200 200 200 2
10.4.6 Digital input
Label Description
Refrigerant Program level
R134 R134a with defrost R404A 1 2
i1P Digital input polarity cL cL cL 2
i1F Digital input configuration dor dor PAL 2
did Digital input alarm delay 15 15 10 2
nPS Number of activation of pressure switch 15 15 5 2
odc Compress and fan status with open door no no no 2
10.4.7 Other
Label Description
Refrigerant Program level
R134 R134a with defrost R404A 1 2
PbC Kind of probe ntC ntC ntC 2
OnF on/off key enabling oFF oFF oFF 2
dP1 Room probe display / / / 1
dP2 Evaporator probe display / / / 1
rEL Software release … … … 2
Ptb Map code / / / 2