Frigo Top 10 - 43 | Pordoi 2000 - 4000 5
3.6 Hours of compressor operation
There is a counter (in hours) that saves the compressor operation
hour count. The resolution is 1 hour and the range goes from 0 to
50.000 hours. Saving interval: 5min.
X Press the “Clock” button:
–
The compressor operation count, in hours,
appears on the display. The first value displayed
indicates the thousands.
X Press the “CLOCK” button again:
–
The units of the compressor operation count
appears on the display; preceded by a minus
sign.
Example:
If the saved value is 1511 hours of operation, the first time the
button is pressed “001” (thousands) is displayed. The second time
the “Clock” button is pressed “-511” (units) is displayed.
Fig. 02: ”Thousands” indication
Fig. 03: ”Units” indication
Repeatedly pressing the “Clock” button toggles between the two
values.
During display of the compressor operating hours only the “Clock”
LED remains on.
When no key is pressed for 3s, the instrument goes back to nor-
mal display.
The user cannot reset the saved value. Only Dixell
can reset it, using a special reset procedure.