EasyManua.ls Logo

Webasto Unite - 11.2 General error condition; 11.3 DC 6 mA leakage current sensor behavior

Webasto Unite
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 | Troubleshooting
32 / 37 5111967A OI-II Webasto Unite
11.2 General error condition
1
2
3
4
(0123) 456 78 90
5
If the status information LED is constantly red (1), then turn off the charging station (2) and turn it on again (3). If the LED is still
constantly red (4), then call (5) an authorized service provider.
11.3 DC 6 mA leakage current sensor behavior
This charging station is equipped with a DC leakage current sensor that reacts to DC leakage currents higher than 6 mA.
If the charging station goes into an error state due to DC leakage current, then you must:
l first unplug the charging cable from vehicle, and
l then unplug the charging cable from the charging station
to reset this error.
The 6 mA sensor inside this charging station has daily self-test for proper operation.