20 SRV 590
Assembly
Operating material
Summer Winter SRV
Quality 590
Engine
Engine oil
SAE 10 W 40 0.3 L
Gasoline
Unleaded gaso-
line in accordance
with DIN 51607
3.0 L
Tamper lower part Hydraulic oil HVLPD 68 1.0 L
Fault Possible cause Remedy
Tamper does not
start
Operating error
Execute the start process
as prescribed
Lack of fuel Check the fuel level
Air lter fouled Clean / change air lter
Fuel lter fouled Change the fuel lter
Spark plug fouled
Clean, adjust, replace the
spark plug
Oil level too low Top off with oil
Engine runs but
it does not reach
full speed
The fuel line is incorrectly
mounted
Check the mounting of the
fuel line
or engine runs
but stops after
a short time
Air lter fouled Clean / change air lter
Fuel lter fouled Change the fuel lter
Spark plug fouled Clean, adjust, replace the
spark plug
Fuel cock closed Open fuel cock
Engine runs at full
rpm, tamper does
not tamp or tamps
inadequately
Unclean compac-
tion pattern
Centrifugal clutch is
defective
Repair
Tamping foot is worn Change the tamping foot
Troubleshooting
Operating uids and ll levels