9
Getting Started
Installing the LPG Cylinder
Outside Cabinet Requirements
The cylinder must be placed on the ground outside
and to the right of the cabinet. The maximum size
requirements for cylinders installed outside the
cabinet are:
Cylinder Capacity: 13 kg maximum
Cylinder Height: 587 mm maximum
Cylinder Width: 306 mm maximum
Ground Placement Installation
1) Open cabinet door.
2) Pass the regulator hose (A) out through the side
panel opening.
3) Place the cylinder on the ground, outside the
cabinet, on the right side of the grill.
4) Turn the LPG cylinder so the opening of the valve is
facing forward.
5) Connect the regulator to the LPG cylinder. Refer to
“CONNECTING THE REGULATOR.”