WECON VM AC Drive User Manual V2.0
WECON technology Co., Ltd
- 10 -
Code
Name
Range
Default
Feature
RAM
address
F0.25
Fan Control Option
Ones Place : Run/Stop
Option
0: Fan runs when VFD is
powered on
1: Stop according to VFD
temperature, run when
VFD is running
2: Run according to VFD
temperature, stop when
VFD is stopped
01
0019
F0.26
Reserved
Reserved
2
001A
F1.00
Start Option
Ones Place: Start Option
0: Run according to starting
1: DC braking first and then
star from the starting
frequency
2: Speed tracking and
direction judgment before
starting from the starting
frequency
Tens Place: Speed Tracking
Direction
0: Same as stopping
direction
1: Same as starting
direction
2: Automatic tracking
0
0100
F1.01
Reserved
0
0101
F1.02
Speed Tracking Period
0.01 to 60.00s
0.50s
0102
F1.03
Starting Frequency
0.00 to 60.00Hz
0.50Hz
0103
F1.04
Last Period of Starting
Frequency
0.0 to 50.0s
0.0s
0104
F1.05
Braking Current of
Starting
0.0 to 150.0%
60.0%
0105
F1.06
Braking Period before
Starting
0.0 to 60.0s
1.0s
0106
F1.07
Acceleration &
Deceleration Curve
0: Straight Line
1: S Curve
00
0107
F1.08
S-Curve Starting
Acceleration Speed
20.0% to 100.0%
50.0%
0108
F1.09
S-Curve Starting
Deceleration Speed
20.0% to 100.0%
50.0%
0109