6
ENGLISH
Model
Frame
Equivalent IP20 inverter frame size
Number of power
phases
Inverter supply
nominal
voltage range [V]
ND
(1)
nominal output
current [Arms] -
refer to the table 2
HD
(1)
nominal output
current [Arms] -
refer to the table 3
Surrounding air
temperature [°C (°F)]
Dynamic braking
RFI lter
Weight [kg (lb)]
Availability of option kits
that can be incorporated into the
product
(Refer to the smart code in the user’s
guide chapter 2)
(8)
RFI suppressor
lter
Dynamic braking
Safety stop
24 Vdc external control
power supply
CFW11 0003 T 4 O 54 ...
1
A
3φ
380...480 V
3.6 3.6
-10...40 °C (14 ...104 °F)
Built-in
Optional (the standard product does not have RFI filter)
10
(22)
Yes
No (braking IGBT available in the standard product)
Yes Yes
CFW11 0005 T 4 O 54 ... 3φ 5.0 5.0
CFW11 0007 T 4 O 54 ... 3φ 7.0 5.5
CFW11 0010 T 4 O 54 ... 3φ 10 10
CFW11 0013 T 4 O 54 ... 3φ 13.5 11
CFW11 0017 T 4 O 54 ...
B
3φ 17 13.5
15
(33)
CFW11 0024 T 4 O 54 ... 3φ 24 19
CFW11 0031 T 4 O 54 ... 3φ 31 25
CFW11 0038 T 4 O 54 ...
2
C
3φ 38 33
36
(79)
CFW11 0045 T 4 O 54 ... 3φ 45 38
CFW11 0058 T 4 O 54 ... 3φ 58.5 47
CFW11 0070 T 4 O 54 ...
D
3φ 70.5 61
41
(90)
CFW11 0088 T 4 O 54 ... 3φ 88 73
CFW11 0105 T 4 O 54 ...
3 E
3φ 105 88
Optional
(the standard
product does
not have
braking)
Built-in
80
(176)
No (filter
available in
the standard
product)
Yes Yes Yes
CFW11 0142 T 4 O 54 ... 3φ 142 115
Table 1 b) - CFW-11 IP54 list of models and technical specifications -
380-480 V supply models