RECIPE PARAMETERS
Displays the recipe parameters loaded into the PrimoCombi.
NUMBER OF PRODUCTS Indicates the number of different products you are running with a single
recipe.
NUMBER OF DUMPS Indicates the number of dumps required to reach target weight.
STAGGER TIME Indicates the total time off all bucket openings during a single dump.
TARGET SPEED The speed at which you wish to run the scale at.
EXTERNAL DEVICE PARAMETERS
Displays the external device parameters (a.k.a. ancillary device) loaded into the PrimoCombi. For details
on each field please refer to Configuring Your Hardware.
ENABLE DUMP READY Indicates if the Dump Ready signal is enabled.
ENABLE DUMP REQUEST Indicates if the Dump Request signal is enabled.
ENABLE DUMPING Indicates if the Dumping signal is enabled.
REQUESTED EDGE Indicates which type of edge to trigger the dump.
ENABLE DUMP WITH MEMORY Indicates if the PrimoCombi remembers a dump request is
enabled.
ON TIME Indicates how long the PrimoCombi will enable its signals for.
FORCE DUMP Indicates if Force Dumping is enabled.