9.10 “IZ set”
When this parameter is on, the indicator will attempt to establish a new initial zero
every time the indicator powers on. HB44 limits the amount of weight that can be
initially zeroed to 20% of scale capacity. (This initial zero does not reduce the indicator
capacity.) This parameter is both sealed and audited.
9.11 “lb units”
Select on/off to enable or disable the pounds (lb) units when the Unit key is pressed in
weighing mode. This parameter is both sealed and audited.
9.12 “kg units”
Select on/off to enable or disable the kilograms (kg) units when the Unit key is pressed
in weighing mode. This parameter is both sealed and audited.
9.13 “g units”
Select on/off to enable or disable the grams (g) units when the Unit key is pressed in
weighing mode. This parameter is both sealed and audited.
9.14 “oz units”
Select on/off to enable or disable the ounces (oz) units when the Unit key is pressed in
weighing mode. This parameter is both sealed and audited.
9.15 “Defaults”
Restore all configuration parameters to factory default. This function is sealed and
audited. Restoring factory defaults will require that the indicator be calibrated and
reconfigured before it will weigh.
10 Display Messages
10.1 General Warning/Error Messages
The following warning and error messages may appear at any time that the display is
showing the current weight. They will not be visible when the indicator is displaying a
menu item.
“Setup required”
The indicator is still set to factory defaults, and will require configu-
ration before entering service. This message will clear once the scale capacity (in
“Setup Menu”/“Parameters”) has been set.
“Cal required”
The indicator has not yet been calibrated. This message will clear
once the scale has been calibrated.
14