3. Set parameters.
Move
It sets the moving distance of the machine.
Sample
It sets how many times that CCD shoots and acquires sample or characteristic points.
Interval
It sets the sampling interval distance.
Sampling delay
It sets the delay time before each sampling.
4. Click Execute.
The machine automatically moves and conducts measurement.
(Optional) Click Stop to suspend the sampling process.
5. Click History Record after the measurement finishes.
Magnification factor and CCD-Spindle angle of each measurement will be shown
in history records.
6. Click OK.
Average value of measuring results will be updated as camera parameter.
For repeated measurement, please clear the history record before next
measurement, to avoid possible interference.
Example
Following is parameter setting suggestion.
Moving distance: 22mm
Sampling times: 10
Sampling distance: 20mm
Sampling delay: 300
Setting CCD-spindle Offset
CCD-spindle offset refers to the distance between the camera and the spindle. It
includes X-axis offset and Y-axis offset.
Steps
1. Drill a hole on the workpiece surface.
2. Click Record Pos 1. The system records the current machine coordinates.
WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
- 16 -

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEIHONG ELECTRONIC NcStudio V10 CCD System and is the answer not in the manual?

WEIHONG ELECTRONIC NcStudio V10 CCD System Specifications

General IconGeneral
BrandWEIHONG ELECTRONIC
ModelNcStudio V10 CCD System
CategoryControl Systems
LanguageEnglish