Focal Level
It sets the height in Z-axis when the camera takes clear photos.
Pre-shoot delay
It sets the delay time to stabilize the camera before taking a photo.
Post-shoot delay
It sets the delay time after the camera takes a photo.
Shoot times
It sets how many times the camera takes photos at a shooting position.
4. Click Developer on the left side, and set parameters of developer’s access on
the right.
Click Snap image button to take photos at current position.
It is recommended to check the box Scaling for Three-point shooting.
Setting CCD Working Plane
CCD working plane refers to the XY plane at focal height. To set the working plane is
to set the focal height in Z-axis.
Prerequisite
Well adjust focal length and aperture of the camera lens. See camera lens for details.
Steps
1. Turn the system to Manual mode, Click Vision CCD Parameters
Manufacturer Param Measure to switch to Measure interface.