4. Machining Operations
4.1. System Startup
The system interface is as shown in Fig. 4-1 after power on.
B o o tin g th e s y ste m ...
Fig. 4-1 System start-up interface
After the system is started, Back to REF. Point will be prompted, as shown in Fig. 4-2. Press [ESC] to
cancel this operation. You need to adjust the following related parameters sequentially: port polarity (see
Chapter 4.5), pulse equivalent (see Chapter 4.3), axis output direction (see Chapter 4.2) and machine
stroke (see Chapter 4.4) before homing all the axes.
Back to REF.
Point?
OK ESC
Fig. 4-2 Prompt to home all the axes after system started
4.2. Axis Direction Adjustment
Firstly confirm the positive direction of each axis according to the coordinate system adhering to the
right-hand rule before starting machine debugging.
After fixing the positive direction of each axis following the right-hand rule, manually operate the machine
to check if the axes move correctly. If the direction is opposite, modify the parameter Axis OutpDir.
Take X-axis as an example, manually move the X-axis, only to find it moves oppositely. To solve this
problem, you just need to change the value of X axis in the parameter Axis OutpDir from Positive
(Negative) to Negative (Positive).
Press the Menu key→ 5. Mfr Param→ 2. Axis OutpDir, and then press the [OK] key to enter the
interface as shown below.