5.2 Warning Information
Positive (negative)
limit of X (Y\Z) axis
The polarity of X-axis
positive limit port is wrong.
Enter [Port] function screen
under [System], and modify
the port polarity (refer to
chapter 3.5.1).
X-axis runs into limit switch
directly during motion.
Manually move X-axis away
from limit switch.
There is an error in limit
switch itself.
Check if limit switch works
normally.
Servo alarm of X
(Y\Z) axis
The polarity of X-axis servo
alarm port is wrong.
Enter [Port] function screen
under [System], and modify
the port polarity (refer to
chapter 3.5.1).
There is an error in X-axis
servo driver itself.
Check if X-axis servo driver
works normally.
E-stop button is
pressed.
The polarity of E-stop port is
wrong.
Enter [Port] function screen
under [System], and modify
the port polarity (refer to
chapter 3.5.1).
The E-stop button is
pressed.
Turn the E-stop button
clockwise to make it
bounced.
The polarity of oil level alarm
port is wrong.
Enter [Port] function screen
under [System], and modify
the port polarity (see chapter
3.5.1).
When the oil level line in the
oil pump is below a certain
value, a signal will be sent to
the system to give an alarm.
Check if the oil mass is too
small in the oil pump.
The polarity of spindle alarm
port is wrong.
Enter [Port] function screen
under [System], and modify
the port polarity (see chapter
3.5.1).
There is an error in inverter.
Find the reason based on the
alarm type of inverter.
Related
operations
of backing
to machine
origin
The system has not
returned to the
machine origin, failed
to execute the
operation!
The system has not returned
to machine origin. Whether
the system has to back to
machine origin is decide by
parameter ―Back to
reference point before
mach‖. If it is set as ―true‖, it
is a must to back to the
machine origin before
machining.
Use this function after
executing backing to
machine origin.