Rotary indexing ring TR
Mounting
The output flange must be in a locked position
before the drive housing is displaced. When the
product is delivered, the output flange is in one of
the possible locked positions.
1. Remove the cover [1] by removing the
screws.
2. Remove the four screws [2].
3. Turn the drive housing [3] to the required
position (the illustration shows the drive
housing turned by 90° to the inside).
4. Fit the four screws [4] of the drive housing
and tighten them cross-wise.
P
The toothed belt is correctly tensioned if
it can be manually twisted by - depending
on the length of the toothed belt - 45° to
90° along the longitudinal axis in the center
between the two pulleys.
P
Contact WEISS GmbH if you need the
frequency for adjusting the toothed belt with a
belt tension meter.
Mounting instructions_062019_4.0_en
35 / 79