Page 23
TROUBLE SHOOTING GUIDE
FAULT REASON REMEDY
Overheat
Lights Come
On
Overheating of unit Allow 3—5 minutes of “cool down” time.
Check for short between nozzle and
electrode. Check transistors; as this
component starts to wear, it begins to
draw more current. If condition is not
resettable, take welder to repair agent
for service.
Difficulty in
Arc Starting
Torch assembled incor-
rectly
Check condition of wire
Low voltage problem Check for missing or low voltage
Arc Does Not
Transfer
Loose, missing cable con-
nections
Check tooling for loose or poor ground.
Power supply not recognis-
ing start signal
Check all connections.
Extension
Cables
Ensure that any extension
cables are of adequate
capacity
Low quality/ capacity cables will result
in voltage drops and hinder starting.
Gas Quality Gas quality / purity must
meet the specified stan-
dards.
Try a bottle of gas of higher purity
grade than normally used and see if the
problem persists. Low gas quality or
oxides in gas can oxidise part and con-
taminate the wire during welding.
NOTE: If you are still having difficulty with your welder, do not hesitate to
contact our service team on:
1800 001 1812