Trouble
Possible
Cause
Low
Oil
Pressure
1.
Oil
leaks
(unit
shut-down)
2.
Low
oil
level
or
incorrect
grade
3.
Faulty
oil
pressure
switch
4.
Clogged
oil
filter
5.
Clogged
oil
pump
strainer
6.
Worn
or
fatigued
oil
pressure
relief
valve
spring
7.
Faulty
electrical
circuit
Checking
Oil
Pressure
with
Mechanical
1.
Remove
the
oil
pressure
sender
and
connect
a
mechanical
oil
pressure
gauge
instead.
2.
Electrically
jump
the
oil
pres-
sure
switch
connections.
3.
Start
the
engine,
operate
at
1800
RPM
and
allow
engine
to
warm
up.
4.
Measure
the
oil
pressure.
If
less
than
the
specification,
check
the
lubricating
system.
Gauge
1.
2.
3.
4.
5.
6.
7.
Oil
pressure:
1.75
-
2.5
kg/cm
2
+
.7
kg/cm
2
(25 - 35
PSI + 5
lb/in
2
)
Remedy
Refer
to
above.
Add
oil
to
proper
level
or
change.
Test
and
replace.
Remove and
replace
oil
filter.
Remove and
clean.
Remove and
replace.
Check
circuit
and
repair
as
needed.
NOTE:
Insure
proper
oil
is
being
used
that
meets
temperature
requirements
and
the
A.P.I.
Spec.
of
SE
or
SE/CC.