DC
ELECTRICAL
SYSTEM
Safety
Information
This
circuit
is
designed
and
manufactured
in
compliance
with
united
States
Coast
Guard
Standards
(33
CFR
PART
183).
No
modifica-
tions
may
be made
to
it
by
the
installer
or
user.
It
is
the
installer's
responsibility
to
assure
that
the
installation
of
the
generator
set
and any
remote
start
panels
or
remote
instrument
panels
are
installed
in
compliance
with
the
above
Coast
Guard
Standards.
Failure
to
observe
these
requirements
could
be
the
cause
of
injury.
Circuit
Description
The two
pole
ON
switch
is
operated
to
bypass
the
protective
shut-
down
switches
during
starting.
The
second
pole
provides
a
source
of·
B+
to
the
start
toggle
switch.
While
continuing
to
hold
the
ON
switch
to
provide
B+
to
the
start
switch
and
to
bypass
the
protective
shutdown
switches,
the
start
switch
is
operated
to
cause
the
starter
to
crank
the
engin~.
If
starting
at
the
generator
set,
release
the
start
switch
when
the
generator
is
running.
If
starting
at
a
remote
location,
release
the
start
switch
when
the
green
LED
shines.
Continue
depressing
the
ON
switch.
It
is
only
necessary
to
con-
tinue
holding
the
ON
switch
after
releasing
the
start
switch
until
oil
pressure
is
sufficient
to
close
the
oil
pressure
safety
switch,
pro-
viding
the
normal
B+
path
to
the
ignition
system.
Note
that
it
is
now
impossible
to
energize
the
starter
while
the
generator
is
running
until
one
again
operates
the
ON
switch
first.
While
operating,
the
overspeed
shutdown
module
monitors
engine
RPM
and
will
ground
the
ignition
system
if
it
senses
engine
RPM
at
approximately
2175
RPM.
Should
the
generator
shut
down from
an
overspeed
condition,
the
overspeed
cir.cuit
MUST
be
reset
before
attempting
to
restart
the
generator.
This
is
done
by
simply
depressing
the
STOP
switch
momen-
tarily
and
then
proceeding
with
the
normal
starting
procedure.
SAFETY
WARNING:
It
is
very
important
that
the
overspeed
shut-
down
always
be
installed
and
functioning.
Any
tam-
per
ing
with
the
overspeed
shutdown
module,
which
would
cause
it
to
malfunction,
could
be a
cause
of
injury
should
the
generator
belt-driven
governor
fail
and
cause
the
generator
to
ft
run
awayft.
78