Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures EN 60068-2-1
EN 60068-2-2
Operational Lx10-F2G-12VDC: -40 to +74°C (-40 to
+165°F)
a
Lx10-F2G: -40 to +70°C (-40 to +158°F)
Storage and
transport
-50 to +85°C (-58 to +185°F)
Humidity EN 60068-2-30 Operational 5-95% relative humidity
Storage and
transport
Altitude Operational 2000 m/70 kPa
Service life Operational 10 years
MTBF MIL-HDBK
217F
630,000 hours
Vibration IEC 60068-2-6
(sine)
Operational 3 - 13.2 Hz: 1 mm
13.2 - 100 Hz 0.7 g
5.5 - 30 Hz: 1.5 g
30 - 50 Hz: 0.42 mm
50 - 500 Hz: 4.2 g
b
Shock IEC
60068-2-27
Operational 30 g, 11 ms
100 g, 6 ms
b
Bump IEC
60068-2-27
Operational 10 g, 11 ms
Enclosure EN 60950-1 Zinc Fire enclosure
Weight 0.7 kg
Degree of protection EN 60529 Enclosure IP40
Cooling Convection
a
Refer to "Safety and Regulations" chapter regarding touch temperature
b
Might require Ethernet cables to be fastened close to the unit.
Table 12. Environmental and mechanical conditions
Lynx L110-F2G & L210-F2G 27

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Westermo Lynx SERIES and is the answer not in the manual?

Westermo Lynx SERIES Specifications

General IconGeneral
ModelLynx SERIES
ManagementWeb interface, CLI, SNMP
Operating Temperature-40°C to +70°C
MountingDIN-rail
DimensionsVaries depending on model
WeightVaries depending on model
StandardsIEEE 802.3
CategoryIndustrial Ethernet Switch

Related product manuals