2.5. Compliance Information
2.5.1. Agency Approvals and Standards Compliance
Type
Approval/Compliance
EMC EN/IEC 61000-6-1, Immunity residential environments
EN/IEC 61000-6-2, Immunity industrial environments
EN/IEC 61000-6-4, Emission industrial environments
EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus
Safety EN/IEC/UL 60950-1, IT equipment
Marine
a
DNV GL rules for classification - Ships and offshore units
Environmental
b
NEMA TS 2, Traffic Controller Assemblies with NTCIP Requirements
a
Only valid for Lx10-F2G, 24-48 VDC
b
Only valid for Lx10-F2G-12VDC
Table 2. Agency approvals and standards compliance
2.5.2. FCC Part 15.105 Class A Notice
This product has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference
when the product is operated in a commercial environment.
This product generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the user manual, may cause harmful interference to radio
communications. Operation of this product in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at the users
own expense.
2.5.3. AREMA
L110-F2G-12VDC has been tested according to AREMA Part 11.3.3, 11.5.1 and 11.5.2.
Port
Test Remark
DC Power 3 x U
N
, 80 ms U
N
(max)=24 VDC when powered from a vital signal battery
Table 3. AREMA Part 11.3.3 C.4. - Signal equipment surge withstand capability for DC input port
8 Lynx L110-F2G & L210-F2G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Westermo Lynx SERIES and is the answer not in the manual?

Westermo Lynx SERIES Specifications

General IconGeneral
ModelLynx SERIES
ManagementWeb interface, CLI, SNMP
Operating Temperature-40°C to +70°C
MountingDIN-rail
DimensionsVaries depending on model
WeightVaries depending on model
StandardsIEEE 802.3
CategoryIndustrial Ethernet Switch