Page #10 background imageLoading...
Page #10 background image
Fig 10 Secure pipework
Ensure that pump installation is thoroughly tested before first use.
NOTE - These are all automatic or semi-automatic applications - ensure that isolator
switch is turned on.
BILGE APPLICATION
Gulper® IC with Strainer IC - Place finger over sensor area to check pump is
activated, remove finger and wait for the pump to stop (45 seconds).
Fig 11 Testing Strainer IC
This Whale Gulper® IC is designed to only require minimal maintenance.
WARNING: Before servicing pump, turn off pump and drain water from system.
Annual Checks
Whale advise that the boat's plumbing system is checked annually for
leaks and obstructions. Also a pump electrics check is advisable.
Before inspecting or replacing the diaphragm, disconnect the electrical
supply.
Optimal Performance
Ensure this product is clear of debris
IF THE PUMP IS NOT OPERATING AS EXPECTED:-
Loosen the hose clips to release the pump from plumbing.
Unscrew the Ezi-clamp clamping ring to release the pump head - see Fig
3 - This will release the pump head, and allow easy access to the valves
& diaphragm.
The diaphragm and valves should be checked for any excessive wear,
damage or cracks, and should be replaced if necessary (service kit
AK2050 - replacement pump head).
13. INSTRUCTIONS FOR USE
14. MAINTENANCE