For Service Technician Use Only
DIAGNOSTICS
1-24
n
French-Door Boom Mount Refrigerator

Show XX for 1 second (version format XX YY ZZ)
Blank for 0.5s
Show YY for 1 second (version format XX YY ZZ)
Blank for 0.5s
Show ZZ for 1 second (version format XX YY ZZ)
Keep Blank When Complete

Show XX for 1 second (version format XX YY ZZ)
Blank for 0.5s
Show YY for 1 second (version format XX YY ZZ)
Blank for 0.5s
Show ZZ for 1 second (version format XX YY ZZ)
Keep Blank When Complete

When entering Service Test, the numeric display shows the
current Proximity Sensor Acvaon mode.
“00” indicates no movement.
“01” indicates movement of object/person.
To advance between control mode use “+” or “-” key. Once
desired seng is selected, push “Drawer” key to acvate then
“Max Cool” to exit this mode.

When entering Service Test, the numeric display shows the
current Heater Acvaon mode.
“00” indicates heater controlled by measured humidity.
“01” indicates heater always on.
To advance between control mode use “+” or “-” key. Once
desired seng is selected, push “Drawer” key to acvate then
“Max Cool” to exit this mode.

When entering Service Test, the numeric display shows the
current Heater Acvaon mode.
“00” indicates heater controlled by measured humidity.
“01” indicates heater always ON.
To advance between control mode use “+” or “-” key. Once
desired seng is selected, push “Drawer” key to acvate then
“Max Cool” to exit this mode.

When entering Service Test, the numeric display shows the
current Heater Acvaon mode.
“00” indicates heater controlled by measured humidity.
“01” indicates heater always ON.
To advance between control mode use “+” or “-” key. Once
desired seng is selected, push “Drawer” key to acvate then
“Max Cool” to exit this mode.