Step G - Sanitize, Test and Purge System (cont.)
18
Storage
Tank
Water Supply Shutoff
Valve to Reverse
Osmosis System
HOT COLD
FIG.25
Reverse
Osmosis
Faucet
Kitchen
Faucet
PRESSURETESTTHESYSTEM
NOTE:Completethesanitizingproceduresonthe
precedingpagebeforepressuretesting.
To pressure test the system, complete the following
steps.
1. Open the water supply valve to the Reverse
Osmosis system.
2. Purge air from the house plumbing by opening sev-
eral house faucets. Close faucets when water runs
smooth, with no spurting.
3. Pressure will start to build in the RO system. In
about 2 hours check all fittings and connections.
Check for water leaks. Fix leaks if any are found. If
problems exist, refer to the troubleshooting chart or
call the toll free number below).
NOTE:Whenthesystemisfirstpressurized,water
may''spurt''fromthefaucetairgapholeuntilairis
expelledfromtheROsystem.
Pleasereviewthefollowingoperatingfeatures
beforeusingyourReverseOsmosissystem:
NOTE:Aswithallotherwatersystemapplications,
leaksmayoccur.Becausethesystempressure
buildsslowly,leaksmaynotbeimmediatelyappar-
ent.Recheckforleaks24hoursafterpurgingthe
systemiscomplete.
NOTE:CodesinthestateofMassachusettsrequire
installationbyalicensedplumberanddonotper-
mittheuseofsaddlevalves.
IfyouliveinthestateofMassachusetts,review
plumbingcode248-CMRoftheCommonwealthof
Massachusettsbeforeproceedingwiththeinstalla-
tion.
PURGINGTHESYSTEM
To purge the system, complete the following steps.
1. Open the Reverse Osmosis Faucet and let water
flow through the system for a 24 hour period. Water
flow will be a slow trickle at this time.
NOTE:DonotconsumewaterfromtheROsys-
temuntilpurgingiscomplete.
2. Close the Reverse Osmosis faucet after the 24 hour
purging period is complete.
3. When the purging is finished, your Reverse
Osmosis system is ready for use.
You will not have filtered water immediately. It may
take several hours to fill the storage tank and create
maximum flow from the Reverse Osmosis faucet.
Water will run to the drain while the Reverse
Osmosis system is producing water, even if you are
not drawing water from the Reverse Osmosis faucet.
You may hear a small quantity of water going to the
drain at times when water is not being used. This is
normal. Water going to the drain will automatically
shut off when the storage tank is full.
Water Pressure from the Reverse Osmosis faucet will
be less than your standard faucet.