Page 10
2500CU_ 1_1_11
NORMAL OPERATION & MAINTENANCE
The cooling unit will cycle on and o as needed once the temperature has stabilized and the initial cool-down” has
been completed. The condensate evaporator and temperature equalizer switches may be turned o for normal
operation.
Thermostat: Is preset at 55°F or desired wine temperature.
Condensate evaporator: Switch “On or “O as ambient humidity requires. In areas of high humidity, leave
the switch “On to evaporate excess condensation. In environments of low humidity, leave the switch in the
“O position.
Temperature equalizer: Turn on whenever a temperature dierence is noted between the top and
bottom bottle rows.
Maintenance
WhisperKOOL recommends vacuuming of the condenser ns located in the rear of the cabinet every three months.
A partially obstructed condenser dramatically reduces the eciency of the cooling unit.
Monthly:
Vacuum lters
— Check for unusual noise or vibration
Quarterly:
— Clean lters
o Remove grille/ducting on the evaporator
o Remove the lter covering the coil
o Wash with warm water
o Dry o lter by shaking o excess water